Sign In | Join Free | My fazendomedia.com
China Kronz (guangzhou) Electronics Co., Ltd. logo
Kronz (guangzhou) Electronics Co., Ltd.
Kronz (guangzhou) Electronics Co., Ltd.
Verified Supplier

1 Years

Home > Industrial Power Supply >

LED Indicator Light Industrial Power Supply 240W AC/DC 24V/10A Metal Case

Kronz (guangzhou) Electronics Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

LED Indicator Light Industrial Power Supply 240W AC/DC 24V/10A Metal Case

  • 1
  • 2

Brand Name : KRONZ

Model Number : PRF240-24A30

Certification : CE

Place of Origin : Guangdong, China

MOQ : 10 pieces

Price : Negotiable

Payment Terms : T/T, Western Union, MoneyGram

Supply Ability : 10000 pieces per month

Delivery Time : 5-8 working days

Packaging Details : Paper box packing

Product name : Industrial Power Supply

Output Power : 240W

Nominal Output : 12V/16A

Output Voltage : 24.0-28.0

Case Material : Metal (AL5052,SPCC)

Safety Standards : 24V

Input Voltage Derating : 85VAC-100VAC

Max. Capacitive Load : 40000 μF

Contact Now

Industrial Power Supply 240W AC/DC 24V/10A Metal Case LED Indicated Light​

Product Description


Industrial power supply 240W, 24V/10A provide customers with cost-effective, standard rail-mounted, efficient and energy-saving green power supplies. Provide high stability and high anti-interference power supply for industrial control equipment, machines and other industrial equipment in various harsh environments. The power supply is small in size, light in weight, compact in structure, and standard railmounted, saving customers a lot of space, the product is safe and reliable.
Features:
  • Input voltage:Universal 85 - 264VAC/120 - 370VDC
  • Accepts AC or DC Input(dual-use of same termlnal)
  • Operating amblent temperature range:-40℃ to +70℃
  • High efficiency, high reliability
  • DC OK function
  • Active PFC
  • 150% peak power for 3 seconds of continuous output
  • Power supply start LED indicator light
  • Output short circult, over-current,over-voltage, over-temperature protection
  • Satisfy 5000m altitude applications
  • Overvoltage level II
  • Indoor use

Selection Guide
Model No. Output Power Nominal Output Voltage&Current (Vo/lo) Output Voltage Adjustable Range (V) Efficiency at 230VAC (%) Typ. Max. Capacitive Load (μF)

PRF240-24A30

240 24V/10A 24.0-28.0 94 40000

Input Specifications
Item Operating Conditions Min. Typ. Max. Unit
Input Voltage Range Rated input (certified voltage) 100 -- 240 VAC
AC input 85 -- 264
DC input 120 -- 370 VDC
Input Voltage Frequency Rated AC input 50 -- 60 Hz
AC input 47 -- 63
Input Current Rated input -- -- 3 A
115VAC -- -- 3
230VAC -- -- 1.5
Inrush Current 115VAC Cold start -- 15 --
230VAC -- 30 --
Leakage Current 264VAC <0.5mA
Power Factor 115VAC -- 0.98 -- --
230VAC -- 0.94 --
Hot Plug Unavailable

Output Specifications
Item Operating Conditions Min. Typ. Max. Unit
Output Voltage Accuracy Full load range 24V -- ±1.0 -- %
Line Regulation Rated load -- ±0.5 --
Load Regulation 0% - 100% load -- ±1.0 --
Ripple & Nolse 20MHz bandwidth
(peak-peak value)
24V -- 60 120 mv
Standby Power -- 4 -- W
Power-off retention time -- 20 -- ms
DC OK Function Resistive load 30VDC/1A Max.
Short Circuit
Protection
Recovery time <10s after the short circuit disappear Hiccup mode,constant current works 1s,turn off
10s,continuous,self-recovery
Over-current
Protection
230VAC,rated load Normal temperature,
high temperature
110%-200%lo,self recovery
Low temperature ≥105% lo, self recovery
Over-voltage
Protection
24V ≤35V Hiccup, can self recover after the abnormal
state is resolved
Over-temperature
Protection
230VAC rated load Over-temperature protection start -- 80 --

Note:The"tip and barrel method"is used for ripple and noise test,output parallel 47uF electrolytic capacitor and 0.1uF ceramic capacitor,please refer to

Enclosed Switching Power Supply Application Notes for specific information;
2.*DC OK Signal: When the output voltage is normal, the relay is connected. When the output voltage is abnormal(<90%Vo),the relay is disconnected.

General Specifications
Item Operating Conditions Min. Typ. Max. Unit
Isolation
Test
Input- Electric strength test for 1min,leakage current<15mA 2000 -- -- VAC
Input-Output 3000 -- --
Output- 500 -- --
Insulation
Resistance
Input- Test voltage: 500VDC 50 -- --
Input-Output 50 -- --
Output- 50 -- --
Operating Temperature -40 -- +70
Storage Temperature -40 -- +85
Storage Humidity Non-condensing -- -- 95 %RH
Operating Humidity -- -- 90
Switching Frequency -- 100 -- kHz
Output Power Derating Operating temperature derating -40℃ to -25 ℃ 3.34 -- -- %℃
+45℃ to +70 ℃ 115VAC 2.0 -- --
+50℃ to +70 ℃ 230VAC 1.25 -- --
+60℃ to +70 ℃ 230VAC 2.5 -- --
Input voltage derating 85VAC-100VAC 0.67 -- -- %VAC
Safety Standards 24V UL61010-1,UL61010-2-201,IS13252(part1)&EN62368-1. Conform to IEC/UL/BS EN 62368-1
Safety Class CLASS I
MTBF MIL-HDBK-217F@25℃ >300,000 h
Pollution Degree 2

Physical Characteristics
Case Material Metal (AL5052,SPCC)
Dimensions 124.00 x 41.00 x 110.00 mm
Weight 650g (Typ.)
Cooling Method Free air convection

EMC Characteristics
EMI CE CISPR32/EN55032 CLASS B
RE CISPR32/EN55032 CLASS B
Harmonic current IEC/EN 61000-3-2 CLASS A and CLASS D
EMS ESD IEC/EN 61000-4-2 Contact ±8KV/Air ±15KV perf. Criteria A
PS IEC/EN 61000-4-3 10V/m perf. Criteria A
EFT IEC/EN 61000-4-4 ±4KV perf. Criteria A
Surge IEC/EN 61000-4-5 line to line ±2KV/line to ground ±4KV perf. Criteria A
CS IEC/EN61000-4-6 10 Vr.m.s perf. Criteria A
Voltage dips,short interruptions
and voltage variations immunity
IEC/EN61000-4-11 0%, 70% perf. Criteria B


Product Tags:

Industrial Power Supply 240W

      

LED Indicator Light Power Supply 240W

      

10A Metal Case Industrial Power Supply

      
Best LED Indicator Light Industrial Power Supply 240W AC/DC 24V/10A Metal Case wholesale

LED Indicator Light Industrial Power Supply 240W AC/DC 24V/10A Metal Case Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Kronz (guangzhou) Electronics Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)